GNL-IN121 -
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-IN121 is based on microprocessor, and keeps frequency current sensor as measuring point with intelligence, high accuracy and comprehensive function. It applies to the accurate measurement of oxygen concentration in 0~25.00% nitrogen- oxygen mixed gases. - See more at: http://en.ci-ele.com/8aedb8bf-ef48-4f8c-127a-797c939a6181/0e266f3f-134f-bfa1-4437-f6ee37fdb1dc.shtml#sthash.sNvnkmUs.dpuf
-
40-782B-551 -
Pickering Interfaces Ltd.
The 40-782B-551 (PXI) and 42-782B-551 (PXIe) single transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 50GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
40-782B-541 -
Pickering Interfaces Ltd.
The 40-782B-541 (PXI) and 42-782B-541 (PXIe) single transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 40GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
40-782B-531 -
Pickering Interfaces Ltd.
The 40-782B-531 (PXI) and 42-782B-531 (PXIe) single transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
40-782B-521 -
Pickering Interfaces Ltd.
The 40-782B-521 (PXI) and 42-782B-521 (PXIe) single transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 18GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
SD-31 -
Potomac Instruments, Inc.
The Model SD-31 Synthesizer-Detector is a high output crystal signal generator of precisely known frequency combined with a sensitive, selective detctor for RF bridge measurements of AM antenna impedance. Packaged in a single light-weight battery-powered unit, the SD031 complements bridges such as the General Radio 1606, 916, and the Delta OIB-1.
-
7117 -
Peaceful Thriving Enterprise Co Ltd
This is a low power consumption, high accuracy and stable hand held 6000 counts multi-meter; with special designed IC to support true RMS measurement. It performs measurements of DC voltage/current, true RMS AC voltage/current, resistance, capacitance, frequency, diode, continuity, temperature and non-contact voltage sensing.
-
Precision Acoustics LTD
Cavitation is often induced by an external acoustic field which typically has very high acoustic amplitudes but the acoustic emissions from these cavitation events are significantly smaller. The small acoustic emissions are characterised by well defined spectral peaks at integer harmonics and sub-harmonics relative to the fundamental bubble frequency.
-
40-782B-542 -
Pickering Interfaces Ltd.
The 40-782B-542 (PXI) and 42-782B-542 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 40GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
40-782B-522 -
Pickering Interfaces Ltd.
The 40-782B-522 (PXI) and 42-782B-522 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 18GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
40-782B-532 -
Pickering Interfaces Ltd.
The 40-782B-532 (PXI) and 42-782B-532 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 26.5GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
40-782B-552 -
Pickering Interfaces Ltd.
The 40-782B-552 (PXI) and 42-782B-552 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 50GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Teledyne Marine Odom Hydrographic
The Echotrac MKIII is the only sounder on the market offering you the choice of either a high resolution thermal paper recorder or a full-sized high bright color LCD chart in interchangeable module format. Both high and low channels feature frequency agility, enabling the operator to precisely match the transceiver to almost any existing transducer. This ability minimizes near-surface noise caused by transducer ringing while increasing echo return strength. The MKIII is capable of both shallow and deep water operations and features unsurpassed interfacing flexibility with four serial ports and high speed Ethernet capability for maximum efficiency.
-
GaGe
GaGe high-performance digitizers are renowned for sustaining the maximum effective number of bits (ENOB) over a wide signal frequency range with quality signal conditioning and signal fidelity features. With A/D sampling rates up to 6 GS/s and very deep onboard acquisition memory of up to 16 GB, our high speed PCIe and PXIe digitizers provide optimal combinations of high sampling speeds with 8-bit, 12-bit, 14-bit, and 16-bit high resolution rates with large sampling memory options and high-speed data streaming capabilities.
-
DR068-M1 -
Teledyne Defence & Space
Teledyne Defence & Space (TDS) DR068-M1 Digitising Receiver combines a state of the art broadband frequency measurement receiver with a high dynamic range successive detection log video amplifier to realise a high probability of intercept receiver. Digital signal processing techniques are utitlised to derive pulse parameters which are packaged into a PDW and transferred via a low latency Gigabit Ethernet interface. The DR068-M1 enables new and existing systems to incorporate a wideband high POI pulse detection capability with minimal integrating effort.